iOS & Android · Zero-Login Field Tool

Offline-first fire door inspections for solo inspectors & building managers.

Built for basement stairwells with zero signal. Record UK BS 8214:2026 millimetres, England Reg 10(5) access refusals, or US & Canada NFPA 80 fractional clearances on-device, then share a clean defect PDF and remedial CSV straight from site.

No Login or Cloud Account 100% Local SQLite + Photos UK mm & US Fractions

Interactive Field Reference

UK BS 8214 & US NFPA 80 Fire-Door Gap Checker

Select a standard, tap a door edge on the schematic, and choose your door material or smoke-control rating to verify default clearances offline in your browser.

ClearGap Tolerance Engine Matches ClearGap iOS & Android gap evaluation rules
FD-01 HEAD HINGE LOCK THRESHOLD
UK Door Rating Type (BS 8214:2026)
Measured Gap — Head (mm)
mm
WITHIN TOLERANCE Head: 3 mm

Current Door Edge Readings
Primary Fire-Test Evidence Precedence: Where manufacturer primary fire-test evidence, a global assessment, third-party certification (BM TRADA Q-Mark, Certifire, FIRAS, UL, Intertek), or local Authority Having Jurisdiction (AHJ) approval specifies tolerances or drop-seal systems differing from generic defaults, the primary test evidence and the inspector's recorded determination govern. This reference tool does not certify statutory compliance.

BM TRADA Q-Mark Outer Plug Colour

Indicates fire-resistance rating on certified UK timber fire door leaves.

Yellow · FD30 Blue · FD60 Brown · FD90 Black · FD120

BM TRADA Inner Tree Colour

Indicates certification scope supplied by the manufacturer or processor.

Silver · Complete Doorset Green · Leaf w/ Intumescents Red · Leaf w/o Intumescents Orange · Factory Glazing

Built for Solo Inspectors & Building Managers

No sales demos. No cloud seat tax. Just fast stairwell evidence.

Designed for independent FDIS / BM TRADA inspectors, joiners doing remedials, US/CA facility maintenance leads, and England Regulation 10 Responsible Persons.

60-Second Stairwell Capture

Auto-increment door IDs (FD-01, FD-02), generic QR/barcode tag scan, interactive Gap-Tap schematic, explicit Pass/Fail/N/A with "Pass Remaining", and red arrow/circle photo markup.

UK Reg 10 & BS 8214 + US NFPA 80

Includes England Reg 10(5) timestamped Refused-Access ("Best Endeavours") logging, BM TRADA plug colour pickers, and NFPA 80 Steel vs Wood (>20m vs 20m HM) fractional tolerances.

Defect PDF, Remedial CSV & Re-Inspection

Exports compact Defect-Only PDFs with your logo and finger-drawn signature, Excel-safe Remedial Works CSVs, Re-Inspection Round Cloning with prior defects, and portable .fdcbackup ZIPs.

Free Printable Reference Snippets

UK Reg 10(5) Refusal Log & US NFPA 80 13-Point Checklist

Print these single-page sheets directly from your browser for clipboard checks, or record every round digitally on-device in ClearGap.

UK Reg 10(5) Flat Entrance Door Refused-Access ("Best Endeavours") Log

England (>11m residential blocks): Quarterly checks on communal doors & annual "best endeavours" checks on flat entrance doors. Regulation 10(5) requires retaining timestamped evidence of access attempts, notices, and refusals. (Wales: FSO 2005 Art 17; Scotland: Fire (Scotland) Act 2005 — BS 9999 / BS 8214 applies.)

Standard ClearGap Access Codes: No answer — card left · Written notice issued · Appointment missed · Refused verbal · Refused written · Locked / obstructed · Corridor-side external check only

Door / Flat ID Date & Time Access Status / Attempt Type Notice / Letter Ref Follow-Up Action / RP Escalation Initials
FD-14 / Flat 4B Sample Row No answer — card left Card #1 left under door Issue 7-day written appointment notice HS

Note: Corridor-side visual checks do not verify internal self-closers or hinge-side intumescent seals; do not mark a flat entrance door as defect-free without full internal and external inspection.

US & Canada NFPA 80 Annual 13-Point Checklist & Wood vs Steel Clearance Chart

Mandatory annual swinging fire door verification (NFPA 80 Ch. 5, Sec. 5.2, CMS / Joint Commission / IFC / National Fire Code of Canada). Retain signed inspection records on site for at least 3 years.

Pt NFPA 80 Ch. 5 Mandatory Inspection Point Pass Criteria Summary P / F / N/A
01Labels Present, Legible & UnpaintedFire rating labels on door & frame readable, not painted over P   F
02No Open Holes or BreaksNo unsealed screw holes, splits, or rust-through on leaf/frame P   F
03Glazing, Vision Frames & BeadsListed fire-rated glass & vision kit intact and securely fastened P   F   N/A
04Door, Frame, Hinges & ThresholdAligned, anchored, noncombustible threshold in working order P   F
05No Missing or Broken PartsAll hinge screws, strikes, flush bolts & astragal parts intact P   F
06Pull-Side Clearances (Sec. 6.3.1.7 & 4.8.4)Within material tolerance table below (Head, Jambs, Meeting, Undercut) P   F
07Self-Closing Device OperationCloses active door completely from full open position P   F
08Coordinator Sequencing (Pairs)Inactive leaf closes completely before active leaf latches P   F   N/A
09Positive Self-Latching into StrikeLatch bolt engages strike cleanly from closer cycle without manual push P   F
10No Interfering Auxiliary HardwareNo wedges, kickdown stops, hooks, chains, or taped latches P   F
11No Unapproved Field ModificationsNo unauthorized cutouts, trimming, or prep voiding the listing P   F
12Edge Protection, Gasketing & NFPA 105 SealsIntumescent edges, astragals & smoke/draft seals intact P   F   N/A
13Signage (<5% Area & No Metal Fasteners)Adhesive-only signs covering <5% of door face; no screws/rivets P   F   N/A
NFPA 80 Door Assembly Type Head, Hinge, Lock & Meeting Stile (Sec. 6.3.1.7) Bottom Undercut (Sec. 4.8.4) Common Inspection Error
Steel / Hollow Metal Door 1/16" to 3/16" (1/8" ± 1/16") ≤3/4" max (3/8" dutch / >38") Falsely failing 3/16" on steel doors
Wood Door (>20-min rating) ≤1/8" max ≤3/4" max (3/8" dutch / >38") Allowing 3/16" on 45/60/90-min wood doors
20-min Wood in Hollow Metal Frame 1/16" to 3/16" (1/8" ± 1/16") ≤3/4" max (3/8" dutch / >38") Applying strict >20m rule without checking listing

Inspection observation record prepared by a qualified person. ClearGap software records inspector-entered observations and does not certify statutory compliance. Local AHJ approvals and manufacturer listings always govern.

Simple Solo Pricing · Zero Sales Calls

Try 2 doors free forever. Upgrade only when you need full building reports.

No 7-day auto-charge trial trap. Built specifically for solo inspectors and building managers — 100% local SQLite storage with portable .fdcbackup ZIP backups (no multi-user cloud portal).

Free Forever
£0 / $0

Test the stairwell workflow on site first.

  • Pre-loaded Sample Building (try unlimited edges & photos)
  • 1 user building + 2 lifetime inspected doors
  • All 3 statutory presets (UK Reg 10, BS 8214, NFPA 80)
  • Watermarked Sample PDF export
  • No free trial timer or card required
Flexible Monthly
£29.99/mo UK
$34.99/mo US

Month-to-month access for short remedial bursts.

  • Full Pro access across unlimited buildings & doors
  • Clean PDFs, Remedial CSV, Round Cloner & ZIP backup
  • Cancel anytime via App Store or Google Play settings
  • Zero login or proprietary cloud lock-in
Important Non-Certification Notice: ClearGap is an inspection observation and documentation tool published by FIELDRADAR LTD. ClearGap records inspector-entered measurements, determinations, and photographs and does not inspect, approve, or certify statutory compliance, fire-resistance performance, or building sign-off.