60-Second Stairwell Capture
Auto-increment door IDs (FD-01, FD-02), generic QR/barcode tag scan, interactive Gap-Tap schematic, explicit Pass/Fail/N/A with "Pass Remaining", and red arrow/circle photo markup.
Built for basement stairwells with zero signal. Record UK BS 8214:2026 millimetres, England Reg 10(5) access refusals, or US & Canada NFPA 80 fractional clearances on-device, then share a clean defect PDF and remedial CSV straight from site.
Interactive Field Reference
Select a standard, tap a door edge on the schematic, and choose your door material or smoke-control rating to verify default clearances offline in your browser.
Indicates fire-resistance rating on certified UK timber fire door leaves.
Indicates certification scope supplied by the manufacturer or processor.
Built for Solo Inspectors & Building Managers
Designed for independent FDIS / BM TRADA inspectors, joiners doing remedials, US/CA facility maintenance leads, and England Regulation 10 Responsible Persons.
Auto-increment door IDs (FD-01, FD-02), generic QR/barcode tag scan, interactive Gap-Tap schematic, explicit Pass/Fail/N/A with "Pass Remaining", and red arrow/circle photo markup.
Includes England Reg 10(5) timestamped Refused-Access ("Best Endeavours") logging, BM TRADA plug colour pickers, and NFPA 80 Steel vs Wood (>20m vs 20m HM) fractional tolerances.
Exports compact Defect-Only PDFs with your logo and finger-drawn signature, Excel-safe Remedial Works CSVs, Re-Inspection Round Cloning with prior defects, and portable .fdcbackup ZIPs.
Free Printable Reference Snippets
Print these single-page sheets directly from your browser for clipboard checks, or record every round digitally on-device in ClearGap.
Standard ClearGap Access Codes: No answer — card left · Written notice issued · Appointment missed · Refused verbal · Refused written · Locked / obstructed · Corridor-side external check only
| Door / Flat ID | Date & Time | Access Status / Attempt Type | Notice / Letter Ref | Follow-Up Action / RP Escalation | Initials |
|---|---|---|---|---|---|
| FD-14 / Flat 4B | Sample Row | No answer — card left | Card #1 left under door | Issue 7-day written appointment notice | HS |
Note: Corridor-side visual checks do not verify internal self-closers or hinge-side intumescent seals; do not mark a flat entrance door as defect-free without full internal and external inspection.
| Pt | NFPA 80 Ch. 5 Mandatory Inspection Point | Pass Criteria Summary | P / F / N/A |
|---|---|---|---|
| 01 | Labels Present, Legible & Unpainted | Fire rating labels on door & frame readable, not painted over | P F |
| 02 | No Open Holes or Breaks | No unsealed screw holes, splits, or rust-through on leaf/frame | P F |
| 03 | Glazing, Vision Frames & Beads | Listed fire-rated glass & vision kit intact and securely fastened | P F N/A |
| 04 | Door, Frame, Hinges & Threshold | Aligned, anchored, noncombustible threshold in working order | P F |
| 05 | No Missing or Broken Parts | All hinge screws, strikes, flush bolts & astragal parts intact | P F |
| 06 | Pull-Side Clearances (Sec. 6.3.1.7 & 4.8.4) | Within material tolerance table below (Head, Jambs, Meeting, Undercut) | P F |
| 07 | Self-Closing Device Operation | Closes active door completely from full open position | P F |
| 08 | Coordinator Sequencing (Pairs) | Inactive leaf closes completely before active leaf latches | P F N/A |
| 09 | Positive Self-Latching into Strike | Latch bolt engages strike cleanly from closer cycle without manual push | P F |
| 10 | No Interfering Auxiliary Hardware | No wedges, kickdown stops, hooks, chains, or taped latches | P F |
| 11 | No Unapproved Field Modifications | No unauthorized cutouts, trimming, or prep voiding the listing | P F |
| 12 | Edge Protection, Gasketing & NFPA 105 Seals | Intumescent edges, astragals & smoke/draft seals intact | P F N/A |
| 13 | Signage (<5% Area & No Metal Fasteners) | Adhesive-only signs covering <5% of door face; no screws/rivets | P F N/A |
| NFPA 80 Door Assembly Type | Head, Hinge, Lock & Meeting Stile (Sec. 6.3.1.7) | Bottom Undercut (Sec. 4.8.4) | Common Inspection Error |
|---|---|---|---|
| Steel / Hollow Metal Door | 1/16" to 3/16" (1/8" ± 1/16") | ≤3/4" max (3/8" dutch / >38") | Falsely failing 3/16" on steel doors |
| Wood Door (>20-min rating) | ≤1/8" max | ≤3/4" max (3/8" dutch / >38") | Allowing 3/16" on 45/60/90-min wood doors |
| 20-min Wood in Hollow Metal Frame | 1/16" to 3/16" (1/8" ± 1/16") | ≤3/4" max (3/8" dutch / >38") | Applying strict >20m rule without checking listing |
Inspection observation record prepared by a qualified person. ClearGap software records inspector-entered observations and does not certify statutory compliance. Local AHJ approvals and manufacturer listings always govern.
Simple Solo Pricing · Zero Sales Calls
No 7-day auto-charge trial trap. Built specifically for solo inspectors and building managers — 100% local SQLite storage with portable .fdcbackup ZIP backups (no multi-user cloud portal).
Test the stairwell workflow on site first.
Equivalent to £10.00/mo UK or $12.50/mo US, billed annually via Apple / Google Play.
Month-to-month access for short remedial bursts.